Aliane K, Benmansour S.
Microfacies analysis and depositional model of a complex hybrid carbonate–siliciclastic ramp from the Aptian–Albian of the Central Aurès Basin (NE Algeria). Carbonates and Evaporites [Internet]. 2026;41 (2).
Publisher's VersionAbstract
The development of a mixed carbonate–siliciclastic ramp system along the southern Tethyan margin can be clarified by examining the Aptian–Albian sequence of the Aurès Basin. An extensive cross-section was analysed to constrain the lithological architecture and microfacies distribution along the southern flank of Djebel El Azereg, the most prominent anticline of the area. Lithostratigraphic analysis allows the subdivision of the Aptian–Albian succession into three well-defined units: the Ich Moul Formation, the Dechera Baida Formation, and the Ackliath Azougar Formation. The studied succession is composed of laterally and vertically heterogeneous siliciclastic–carbonate deposits, reflecting the interplay between carbonate productivity and episodic terrigenous input under varying accommodation conditions. Petrographic analysis reveals a diverse suite of microfacies, characterised by significant variations in texture and in the relative abundance of skeletal and non-skeletal components. Thirteen microfacies are distinguished and organised into five facies associations, (1) siliciclastic microfacies, constituted by fine- to medium-grained sandstones; (2) siliciclastic–carbonate microfacies with packstone texture, composed mainly of quartz grains, ooids, bivalves, and orbitolinids; (3 and 4) carbonate microfacies with packstone and/or grainstone texture, dominated by ooids and peloids; and (4) wackestone to packstone microfacies, dominated by bivalves and echinoderms. These facies associations record depositional environments along a low-gradient homoclinal ramp, ranging from coastal and hybrid backshoal settings to carbonate shoals (inner and mid-ramp) and a proximal outer ramp domain. The spatial and vertical distribution of these facies associations provides insights into the internal organisation of the ramp (inner, middle and outer) and its stratigraphic evolution. These results highlight the complex dynamics of mixed carbonate–siliciclastic systems and contribute to a better understanding of Aptian–Albian platform development along the southern Tethyan margin.
Aliane K, Benmansour S.
Microfacies analysis and depositional model of a complex hybrid carbonate–siliciclastic ramp from the Aptian–Albian of the Central Aurès Basin (NE Algeria). Carbonates and Evaporites [Internet]. 2026;41 (2).
Publisher's VersionAbstract
The development of a mixed carbonate–siliciclastic ramp system along the southern Tethyan margin can be clarified by examining the Aptian–Albian sequence of the Aurès Basin. An extensive cross-section was analysed to constrain the lithological architecture and microfacies distribution along the southern flank of Djebel El Azereg, the most prominent anticline of the area. Lithostratigraphic analysis allows the subdivision of the Aptian–Albian succession into three well-defined units: the Ich Moul Formation, the Dechera Baida Formation, and the Ackliath Azougar Formation. The studied succession is composed of laterally and vertically heterogeneous siliciclastic–carbonate deposits, reflecting the interplay between carbonate productivity and episodic terrigenous input under varying accommodation conditions. Petrographic analysis reveals a diverse suite of microfacies, characterised by significant variations in texture and in the relative abundance of skeletal and non-skeletal components. Thirteen microfacies are distinguished and organised into five facies associations, (1) siliciclastic microfacies, constituted by fine- to medium-grained sandstones; (2) siliciclastic–carbonate microfacies with packstone texture, composed mainly of quartz grains, ooids, bivalves, and orbitolinids; (3 and 4) carbonate microfacies with packstone and/or grainstone texture, dominated by ooids and peloids; and (4) wackestone to packstone microfacies, dominated by bivalves and echinoderms. These facies associations record depositional environments along a low-gradient homoclinal ramp, ranging from coastal and hybrid backshoal settings to carbonate shoals (inner and mid-ramp) and a proximal outer ramp domain. The spatial and vertical distribution of these facies associations provides insights into the internal organisation of the ramp (inner, middle and outer) and its stratigraphic evolution. These results highlight the complex dynamics of mixed carbonate–siliciclastic systems and contribute to a better understanding of Aptian–Albian platform development along the southern Tethyan margin.
Bouanaka M-L, Rebiai C, Saidani N.
An enhanced rectangular Membrane Finite Element Based on the Strain Approach. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
This study presents the development of a enhancedrectangular membrane finite element using the strain-based approach, designed for both elasticand elastoplasticanalyses. Each of the four corner nodes of the element is characterized by three degrees of freedom: two translational degrees and one in-plane rotational degree.The displacement functions of the proposed element accurately capture the rigid body motion modes.For the elastoplastic computations, the material response is evaluated using the Von Mises failure creterion, andthe nonlinear solution procedure incorporates viscoplastic-strain approaches. For validation purposes, several selected numerical examples are solved using the developed element in both linear and nonlinearanalyses.The results obtained are compared with analytical solutions and other similar membrane finite elements, demonstrating the strong performance of the proposed element.
Bouanaka M-L, Rebiai C, Saidani N.
An enhanced rectangular Membrane Finite Element Based on the Strain Approach. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
This study presents the development of a enhancedrectangular membrane finite element using the strain-based approach, designed for both elasticand elastoplasticanalyses. Each of the four corner nodes of the element is characterized by three degrees of freedom: two translational degrees and one in-plane rotational degree.The displacement functions of the proposed element accurately capture the rigid body motion modes.For the elastoplastic computations, the material response is evaluated using the Von Mises failure creterion, andthe nonlinear solution procedure incorporates viscoplastic-strain approaches. For validation purposes, several selected numerical examples are solved using the developed element in both linear and nonlinearanalyses.The results obtained are compared with analytical solutions and other similar membrane finite elements, demonstrating the strong performance of the proposed element.
Bouanaka M-L, Rebiai C, Saidani N.
An enhanced rectangular Membrane Finite Element Based on the Strain Approach. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
This study presents the development of a enhancedrectangular membrane finite element using the strain-based approach, designed for both elasticand elastoplasticanalyses. Each of the four corner nodes of the element is characterized by three degrees of freedom: two translational degrees and one in-plane rotational degree.The displacement functions of the proposed element accurately capture the rigid body motion modes.For the elastoplastic computations, the material response is evaluated using the Von Mises failure creterion, andthe nonlinear solution procedure incorporates viscoplastic-strain approaches. For validation purposes, several selected numerical examples are solved using the developed element in both linear and nonlinearanalyses.The results obtained are compared with analytical solutions and other similar membrane finite elements, demonstrating the strong performance of the proposed element.
HOUAS N, ATMANI Y, Rebiai C.
A NEW STRAIN-BASED TRIANGULAR ELEMENT FOR 2D STRUCTURAL ANALYSIS. ACADEMIC JOURNAL OF MANUFACTURING ENGINEERING [Internet]. 2026;24 (2).
Publisher's VersionAbstract
This work presents a novel strain-based finite element formulation specifically designed for the comprehensive analysis of two-dimensional structures under static and dynamic elastoplastic conditions. The proposed triangular element features three degrees of freedom per node, including two in-plane translational components and one rotational component about the normal axis.The displacement field is derived from predefined strain functions that satisfy the compatibility equations, while the interpolation functions are carefully constructed to provide an exact representation of rigid body motions. The developed formulation is applicable to both static and time-dependent elastoplastic analyses.In the static case, the element accurately determines nodal forces, displacements, and stress distributions. For dynamic analyses, a lumped mass matrix combined with an explicit time integration scheme is adopted to improve computational efficiency.The accuracy and robustness of the proposed element are validated through several benchmark test problems, demonstrating its excellent numerical performance and reliability in structural analysis.
HOUAS N, ATMANI Y, Rebiai C.
A NEW STRAIN-BASED TRIANGULAR ELEMENT FOR 2D STRUCTURAL ANALYSIS. ACADEMIC JOURNAL OF MANUFACTURING ENGINEERING [Internet]. 2026;24 (2).
Publisher's VersionAbstract
This work presents a novel strain-based finite element formulation specifically designed for the comprehensive analysis of two-dimensional structures under static and dynamic elastoplastic conditions. The proposed triangular element features three degrees of freedom per node, including two in-plane translational components and one rotational component about the normal axis.The displacement field is derived from predefined strain functions that satisfy the compatibility equations, while the interpolation functions are carefully constructed to provide an exact representation of rigid body motions. The developed formulation is applicable to both static and time-dependent elastoplastic analyses.In the static case, the element accurately determines nodal forces, displacements, and stress distributions. For dynamic analyses, a lumped mass matrix combined with an explicit time integration scheme is adopted to improve computational efficiency.The accuracy and robustness of the proposed element are validated through several benchmark test problems, demonstrating its excellent numerical performance and reliability in structural analysis.
HOUAS N, ATMANI Y, Rebiai C.
A NEW STRAIN-BASED TRIANGULAR ELEMENT FOR 2D STRUCTURAL ANALYSIS. ACADEMIC JOURNAL OF MANUFACTURING ENGINEERING [Internet]. 2026;24 (2).
Publisher's VersionAbstract
This work presents a novel strain-based finite element formulation specifically designed for the comprehensive analysis of two-dimensional structures under static and dynamic elastoplastic conditions. The proposed triangular element features three degrees of freedom per node, including two in-plane translational components and one rotational component about the normal axis.The displacement field is derived from predefined strain functions that satisfy the compatibility equations, while the interpolation functions are carefully constructed to provide an exact representation of rigid body motions. The developed formulation is applicable to both static and time-dependent elastoplastic analyses.In the static case, the element accurately determines nodal forces, displacements, and stress distributions. For dynamic analyses, a lumped mass matrix combined with an explicit time integration scheme is adopted to improve computational efficiency.The accuracy and robustness of the proposed element are validated through several benchmark test problems, demonstrating its excellent numerical performance and reliability in structural analysis.
Bouakkar L, Ameddah H, Mazouz H.
Reliability-Based Design Optimization of Hip Prosthesis Jump Distance: Monte Carlo Analysis of 1,617 Design Configurations. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
This study presents a reliability-based design optimization (RBDO) framework for improving the intrinsic stability of total hip arthroplasty through jump-distance-based design selection. The problem was formulated using four design variables: femoral head diameter, cup abduction angle, cup anteversion angle, and femoral offset. Jump distance (JD) was computed from an analytical geometric model, and uncertainty was propagated by Monte Carlo simulation with 10,000 samples per scenario. A total of 1,617 configurations were evaluated in MATLAB R2020b using parallel computing. The results showed a mean reliability index of 2.3945, with values ranging from -2.9677 to 3.8906, and a mean Monte Carlo jump distance of 12.0659 mm. The best-performing configuration within the explored design space was a 36 mm head, 30° abduction, 30° anteversion, and -2 mm offset, yielding a nominal JD of 20.601 mm, a mean simulated JD of 20.568 mm, and zero failures in 10,000 trials. Parametric analysis showed that abduction angle had the strongest negative influence on reliability, followed by femoral offset, whereas head diameter had a positive effect and anteversion had a weaker but favorable contribution. These results confirm that a probabilistic design framework can discriminate robust from fragile implant configurations more effectively than a purely deterministic threshold check and provide a computationally efficient basis for preclinical implant-orientation optimization.
Bouakkar L, Ameddah H, Mazouz H.
Reliability-Based Design Optimization of Hip Prosthesis Jump Distance: Monte Carlo Analysis of 1,617 Design Configurations. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
This study presents a reliability-based design optimization (RBDO) framework for improving the intrinsic stability of total hip arthroplasty through jump-distance-based design selection. The problem was formulated using four design variables: femoral head diameter, cup abduction angle, cup anteversion angle, and femoral offset. Jump distance (JD) was computed from an analytical geometric model, and uncertainty was propagated by Monte Carlo simulation with 10,000 samples per scenario. A total of 1,617 configurations were evaluated in MATLAB R2020b using parallel computing. The results showed a mean reliability index of 2.3945, with values ranging from -2.9677 to 3.8906, and a mean Monte Carlo jump distance of 12.0659 mm. The best-performing configuration within the explored design space was a 36 mm head, 30° abduction, 30° anteversion, and -2 mm offset, yielding a nominal JD of 20.601 mm, a mean simulated JD of 20.568 mm, and zero failures in 10,000 trials. Parametric analysis showed that abduction angle had the strongest negative influence on reliability, followed by femoral offset, whereas head diameter had a positive effect and anteversion had a weaker but favorable contribution. These results confirm that a probabilistic design framework can discriminate robust from fragile implant configurations more effectively than a purely deterministic threshold check and provide a computationally efficient basis for preclinical implant-orientation optimization.
Bouakkar L, Ameddah H, Mazouz H.
Reliability-Based Design Optimization of Hip Prosthesis Jump Distance: Monte Carlo Analysis of 1,617 Design Configurations. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
This study presents a reliability-based design optimization (RBDO) framework for improving the intrinsic stability of total hip arthroplasty through jump-distance-based design selection. The problem was formulated using four design variables: femoral head diameter, cup abduction angle, cup anteversion angle, and femoral offset. Jump distance (JD) was computed from an analytical geometric model, and uncertainty was propagated by Monte Carlo simulation with 10,000 samples per scenario. A total of 1,617 configurations were evaluated in MATLAB R2020b using parallel computing. The results showed a mean reliability index of 2.3945, with values ranging from -2.9677 to 3.8906, and a mean Monte Carlo jump distance of 12.0659 mm. The best-performing configuration within the explored design space was a 36 mm head, 30° abduction, 30° anteversion, and -2 mm offset, yielding a nominal JD of 20.601 mm, a mean simulated JD of 20.568 mm, and zero failures in 10,000 trials. Parametric analysis showed that abduction angle had the strongest negative influence on reliability, followed by femoral offset, whereas head diameter had a positive effect and anteversion had a weaker but favorable contribution. These results confirm that a probabilistic design framework can discriminate robust from fragile implant configurations more effectively than a purely deterministic threshold check and provide a computationally efficient basis for preclinical implant-orientation optimization.
Nacer S, Benhizia A, Khennab A, Bensalem I.
Modeling and prediction of the mechanical properties of foam-based composites with complex microstructures. Mechanics of Advanced Materials and Structures [Internet]. 2026;33 (1).
Publisher's VersionAbstract
Foam-based composites are advanced materials that combine lightweight design with high mechanical strength and stiffness, making them attractive for diverse engineering applications. Their mechanical performance is strongly influenced by foam morphology, including strut geometry in open-cell foams and cell wall topology in closed-cell foams. This study investigates the effect of these morphological features on the mechanical behavior of foam-based composites, considering both open-cell and closed-cell foams as matrix phases. A finite element-based numerical homogenization approach evaluates mechanical performance over a wide range of phase volume fractions and stiffness contrasts. The results reveal significant differences in stress distribution, load transfer efficiency, and overall mechanical response between the two foam morphologies. Open-cell foam composites, particularly those with cylindrical struts, show superior load-bearing capacity under high stiffness contrast. In contrast, closed-cell composites develop stress localization unless optimized with thin walls and dense reinforcement. The findings indicate that the mechanical efficiency is governed by three main factors: (i) phase stiffness contrast, determining how morphology affects performance; (ii) phase connectivity or interpenetration, controlling stress transfer through the stiff phase; and (iii) strut geometry, where rounded struts aligned with the load enable direct stress transfer while minimizing matrix deformation.
Nacer S, Benhizia A, Khennab A, Bensalem I.
Modeling and prediction of the mechanical properties of foam-based composites with complex microstructures. Mechanics of Advanced Materials and Structures [Internet]. 2026;33 (1).
Publisher's VersionAbstract
Foam-based composites are advanced materials that combine lightweight design with high mechanical strength and stiffness, making them attractive for diverse engineering applications. Their mechanical performance is strongly influenced by foam morphology, including strut geometry in open-cell foams and cell wall topology in closed-cell foams. This study investigates the effect of these morphological features on the mechanical behavior of foam-based composites, considering both open-cell and closed-cell foams as matrix phases. A finite element-based numerical homogenization approach evaluates mechanical performance over a wide range of phase volume fractions and stiffness contrasts. The results reveal significant differences in stress distribution, load transfer efficiency, and overall mechanical response between the two foam morphologies. Open-cell foam composites, particularly those with cylindrical struts, show superior load-bearing capacity under high stiffness contrast. In contrast, closed-cell composites develop stress localization unless optimized with thin walls and dense reinforcement. The findings indicate that the mechanical efficiency is governed by three main factors: (i) phase stiffness contrast, determining how morphology affects performance; (ii) phase connectivity or interpenetration, controlling stress transfer through the stiff phase; and (iii) strut geometry, where rounded struts aligned with the load enable direct stress transfer while minimizing matrix deformation.
Nacer S, Benhizia A, Khennab A, Bensalem I.
Modeling and prediction of the mechanical properties of foam-based composites with complex microstructures. Mechanics of Advanced Materials and Structures [Internet]. 2026;33 (1).
Publisher's VersionAbstract
Foam-based composites are advanced materials that combine lightweight design with high mechanical strength and stiffness, making them attractive for diverse engineering applications. Their mechanical performance is strongly influenced by foam morphology, including strut geometry in open-cell foams and cell wall topology in closed-cell foams. This study investigates the effect of these morphological features on the mechanical behavior of foam-based composites, considering both open-cell and closed-cell foams as matrix phases. A finite element-based numerical homogenization approach evaluates mechanical performance over a wide range of phase volume fractions and stiffness contrasts. The results reveal significant differences in stress distribution, load transfer efficiency, and overall mechanical response between the two foam morphologies. Open-cell foam composites, particularly those with cylindrical struts, show superior load-bearing capacity under high stiffness contrast. In contrast, closed-cell composites develop stress localization unless optimized with thin walls and dense reinforcement. The findings indicate that the mechanical efficiency is governed by three main factors: (i) phase stiffness contrast, determining how morphology affects performance; (ii) phase connectivity or interpenetration, controlling stress transfer through the stiff phase; and (iii) strut geometry, where rounded struts aligned with the load enable direct stress transfer while minimizing matrix deformation.
Nacer S, Benhizia A, Khennab A, Bensalem I.
Modeling and prediction of the mechanical properties of foam-based composites with complex microstructures. Mechanics of Advanced Materials and Structures [Internet]. 2026;33 (1).
Publisher's VersionAbstract
Foam-based composites are advanced materials that combine lightweight design with high mechanical strength and stiffness, making them attractive for diverse engineering applications. Their mechanical performance is strongly influenced by foam morphology, including strut geometry in open-cell foams and cell wall topology in closed-cell foams. This study investigates the effect of these morphological features on the mechanical behavior of foam-based composites, considering both open-cell and closed-cell foams as matrix phases. A finite element-based numerical homogenization approach evaluates mechanical performance over a wide range of phase volume fractions and stiffness contrasts. The results reveal significant differences in stress distribution, load transfer efficiency, and overall mechanical response between the two foam morphologies. Open-cell foam composites, particularly those with cylindrical struts, show superior load-bearing capacity under high stiffness contrast. In contrast, closed-cell composites develop stress localization unless optimized with thin walls and dense reinforcement. The findings indicate that the mechanical efficiency is governed by three main factors: (i) phase stiffness contrast, determining how morphology affects performance; (ii) phase connectivity or interpenetration, controlling stress transfer through the stiff phase; and (iii) strut geometry, where rounded struts aligned with the load enable direct stress transfer while minimizing matrix deformation.
Bouras A, Hellalet S.
Authentic Audiovisual Input And Perceived Speaking Skills Among Efl Learners: Case Of Second Year Efl Students, Batna2 University. Afak for sciences journal [Internet]. 2026;11 (2) :408-426.
Publisher's VersionAbstract
This study investigates how authentic audiovisual (AAV) materials, particularly TED Talks and YouTube videos, contribute to second-year EFL students’ perceived speaking development at Batna2 University. To obtain the required data, 130 second-year students completed a questionnaire that measured three constructs, including the profiled AAV engagement, instructional use in-class vs. homework, and perceived gains across five speaking dimensions, in addition to Semi-structured interviews with seven teachers, who explored classroom practices, constraints, and conditions for effectiveness. The findings indicate positive student perceptions of AAV input, as evidenced by higher engagement with AAV content. It is also reported that the strongest perceived gains were in confidence/anxiety reduction and pronunciation/intonation awareness, while perceived gains in fluency were comparatively lower. At the same time, Teachers' views converged on one key condition: AAV materials are perceived as most beneficial when viewing is systematically linked to structured speaking tasks and supported by pedagogical scaffolding.
Bouras A, Hellalet S.
Authentic Audiovisual Input And Perceived Speaking Skills Among Efl Learners: Case Of Second Year Efl Students, Batna2 University. Afak for sciences journal [Internet]. 2026;11 (2) :408-426.
Publisher's VersionAbstract
This study investigates how authentic audiovisual (AAV) materials, particularly TED Talks and YouTube videos, contribute to second-year EFL students’ perceived speaking development at Batna2 University. To obtain the required data, 130 second-year students completed a questionnaire that measured three constructs, including the profiled AAV engagement, instructional use in-class vs. homework, and perceived gains across five speaking dimensions, in addition to Semi-structured interviews with seven teachers, who explored classroom practices, constraints, and conditions for effectiveness. The findings indicate positive student perceptions of AAV input, as evidenced by higher engagement with AAV content. It is also reported that the strongest perceived gains were in confidence/anxiety reduction and pronunciation/intonation awareness, while perceived gains in fluency were comparatively lower. At the same time, Teachers' views converged on one key condition: AAV materials are perceived as most beneficial when viewing is systematically linked to structured speaking tasks and supported by pedagogical scaffolding.
HARROUG M-R, Ameddah H, Mazouz H.
Multiscale Computational Design of Ti-6Al-4V/SiC Composite Femoral Stems: SIMP Topology Optimisation, Functionally Graded TPMS Lattices. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
Aseptic loosening driven by stress shielding remains the principal long-term failure mode of total hip arthroplasty (THA), affecting 10-15% of implants within 15 years and generating annual revision costs exceeding USD 8 billion globally. This study presents an integrated multiscale computational framework for the design of functionally graded femoral stems using Ti-6Al-4V/SiC whisker-reinforced composite materials. The framework systematically couples seven sequential modules : (M1) Halpin-Tsai micromechanical characterisation of three material systems Ti-6Al-4V, Ti/SiC 20 vol%, and Ti/SiC 40 vol%; (M2) analytical beam stress analysis under ISO 7206-4 oblique cantilever loading; (M3) SIMP topology optimisation at V* = 0.70 achieving 30% mass reduction (C/C₀= 0.37), (M4) TPMS lattice homogenisation for four architectures (Gyroid, Diamond, Cubic, Octet) with a corrected stress shielding index (SSI_Gyroid = +11.1%) representing an 87% reduction from monolithic Ti-6Al-4V (SSI = 82.5%), (M5) multiaxial fatigue analysis combining Rainflow cycle counting, modified Goodman criterion, and dual Miner damage reporting (D_ISO = 0.001-0.018; D_full = 0.117-1.426. The Ti/SiC 20 vol% composite in a functionally graded Gyroid architecture emerges as the optimal clinical configuration, uniquely satisfying all biomechanical, osseointegration, and SLM fabricability requirements simultaneously.Keywords:total hip arthroplasty; stress shielding; SIMP topology optimisation; TPMS lattice; Ti-6Al-4V/SiC composite; Goodman criterion; Miner damage; functionally graded implant.
HARROUG M-R, Ameddah H, Mazouz H.
Multiscale Computational Design of Ti-6Al-4V/SiC Composite Femoral Stems: SIMP Topology Optimisation, Functionally Graded TPMS Lattices. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
Aseptic loosening driven by stress shielding remains the principal long-term failure mode of total hip arthroplasty (THA), affecting 10-15% of implants within 15 years and generating annual revision costs exceeding USD 8 billion globally. This study presents an integrated multiscale computational framework for the design of functionally graded femoral stems using Ti-6Al-4V/SiC whisker-reinforced composite materials. The framework systematically couples seven sequential modules : (M1) Halpin-Tsai micromechanical characterisation of three material systems Ti-6Al-4V, Ti/SiC 20 vol%, and Ti/SiC 40 vol%; (M2) analytical beam stress analysis under ISO 7206-4 oblique cantilever loading; (M3) SIMP topology optimisation at V* = 0.70 achieving 30% mass reduction (C/C₀= 0.37), (M4) TPMS lattice homogenisation for four architectures (Gyroid, Diamond, Cubic, Octet) with a corrected stress shielding index (SSI_Gyroid = +11.1%) representing an 87% reduction from monolithic Ti-6Al-4V (SSI = 82.5%), (M5) multiaxial fatigue analysis combining Rainflow cycle counting, modified Goodman criterion, and dual Miner damage reporting (D_ISO = 0.001-0.018; D_full = 0.117-1.426. The Ti/SiC 20 vol% composite in a functionally graded Gyroid architecture emerges as the optimal clinical configuration, uniquely satisfying all biomechanical, osseointegration, and SLM fabricability requirements simultaneously.Keywords:total hip arthroplasty; stress shielding; SIMP topology optimisation; TPMS lattice; Ti-6Al-4V/SiC composite; Goodman criterion; Miner damage; functionally graded implant.
HARROUG M-R, Ameddah H, Mazouz H.
Multiscale Computational Design of Ti-6Al-4V/SiC Composite Femoral Stems: SIMP Topology Optimisation, Functionally Graded TPMS Lattices. Journal of Information Systems Engineering and Management [Internet]. 2026;11 (3s).
Publisher's VersionAbstract
Aseptic loosening driven by stress shielding remains the principal long-term failure mode of total hip arthroplasty (THA), affecting 10-15% of implants within 15 years and generating annual revision costs exceeding USD 8 billion globally. This study presents an integrated multiscale computational framework for the design of functionally graded femoral stems using Ti-6Al-4V/SiC whisker-reinforced composite materials. The framework systematically couples seven sequential modules : (M1) Halpin-Tsai micromechanical characterisation of three material systems Ti-6Al-4V, Ti/SiC 20 vol%, and Ti/SiC 40 vol%; (M2) analytical beam stress analysis under ISO 7206-4 oblique cantilever loading; (M3) SIMP topology optimisation at V* = 0.70 achieving 30% mass reduction (C/C₀= 0.37), (M4) TPMS lattice homogenisation for four architectures (Gyroid, Diamond, Cubic, Octet) with a corrected stress shielding index (SSI_Gyroid = +11.1%) representing an 87% reduction from monolithic Ti-6Al-4V (SSI = 82.5%), (M5) multiaxial fatigue analysis combining Rainflow cycle counting, modified Goodman criterion, and dual Miner damage reporting (D_ISO = 0.001-0.018; D_full = 0.117-1.426. The Ti/SiC 20 vol% composite in a functionally graded Gyroid architecture emerges as the optimal clinical configuration, uniquely satisfying all biomechanical, osseointegration, and SLM fabricability requirements simultaneously.Keywords:total hip arthroplasty; stress shielding; SIMP topology optimisation; TPMS lattice; Ti-6Al-4V/SiC composite; Goodman criterion; Miner damage; functionally graded implant.