<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">COMMANDE A FLUX VIRTUEL ORIENTE DE LA GENERATRICE ASYNCHRONE A CAGE DOUBLE ÉTOILE</style></title><secondary-title><style face="normal" font="default" size="100%">Revue Roumaine des Sciences Techniques - Serie Électrotechnique et Énergétique</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08</style></date></pub-dates></dates><pages><style face="normal" font="default" size="100%">2021</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Cet article est consacré à l’étude des performances de la génératrice asynchrone à cage double étoile (GASDE) en site isolé. Le système de commande est composé d’une GASDE raccordé à un bus continu et une charge en sortie de deux redresseurs à commande MLI. Une étude comparative entre la technique de commande conventionnelle et la commande adaptée basée sur l’introduction de la SVM-PI-flou et un nouvel estimateur de flux (flux virtuel statorique) afin d’améliorer la qualité d’énergie et d’atténuer les harmoniques du courant.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Deboucha, Abdelhakim</style></author><author><style face="normal" font="default" size="100%">Bentouhami, Larafi</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Super twisting sliding mode approach applied to voltage orientated control of a stand-alone induction generator</style></title><secondary-title><style face="normal" font="default" size="100%">Protection and Control of Modern Power Systems</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">https://pcmp.springeropen.com/articles/10.1186/s41601-021-00201-2</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">6</style></volume><pages><style face="normal" font="default" size="100%">18</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">To enhance the robustness and dynamic performance of a self-excited induction generator (SEIG) used in a stand-alone wind energy system (WES), a virtual flux oriented control (VFOC) based on nonlinear super-twisting sliding mode control (STSMC) is adopted. STSMC is used to replace the conventional proportional-integral-Fuzzy Logic Controller (PI-FLC) of the inner current control loops. The combination of the proposed control strategy with space vector modulation (SVM) applied to a PWM rectifier brings many advantages such as reduction in harmonics, and precise and rapid tracking of the references. The performance of the proposed control technique (STSMC-VFOC-SVM) is verified through simulations and compared with the traditional technique (PI-FLC-VFOC-SVM). It shows that the proposed method improves the dynamics of the system with reduced current harmonics. In addition, the use of a virtual flux estimator instead of a phase-locked loop (PLL) eliminates the line voltage sensors and thus increases the reliability of the system.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">COMMANDE A FLUX VIRTUEL ORIENTE DE LA GENERATRICE ASYNCHRONE A CAGE DOUBLE ÉTOILE</style></title><secondary-title><style face="normal" font="default" size="100%">Revue Roumaine des Sciences Techniques - Serie Électrotechnique et Énergétique</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08 2021</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">https://journal.iem.pub.ro/rrst-ee/article/download/51/35</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">66</style></volume><pages><style face="normal" font="default" size="100%">2021</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p style=&quot;text-align: justify;&quot;&gt;
	Cet article est consacré à l’étude des performances de la génératrice asynchrone à cage double étoile (GASDE) en site isolé. Le système de commande est composé d’une GASDE raccordé à un bus continu et une charge en sortie de deux redresseurs à commande MLI. Une étude comparative entre la technique de commande conventionnelle et la commande adaptée basée sur l’introduction de la SVM-PI-flou et un nouvel estimateur de flux (flux virtuel statorique) afin d’améliorer la qualité d’énergie et d’atténuer les harmoniques du courant.
&lt;/p&gt;
</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">DIRECTIONAL VIRTUAL FLOW CONTROL OF THE DOUBLE STAR CAGE ASYNCHRONOUS GENERATOR</style></title><secondary-title><style face="normal" font="default" size="100%">Revue Roumaine des Sciences Techniques—Série Électrotechnique et Énergétique</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2021</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">https://journal.iem.pub.ro/rrst-ee/article/view/51</style></url></web-urls></urls><number><style face="normal" font="default" size="100%">2</style></number><volume><style face="normal" font="default" size="100%">66</style></volume><pages><style face="normal" font="default" size="100%">71-76</style></pages><isbn><style face="normal" font="default" size="100%">0035-4066</style></isbn><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p style=&quot;text-align: justify;&quot;&gt;
	This article is devoted to the study of the performance of the double star cage asynchronous generator (GASDE) in isolated site. The control system consists of a GASDE connected to a dc bus and a load at the output of two PWM control rectifiers. A comparative study between the conventional control technique and the adapted control based on the introduction of the SVM- PI-fuzzy and a new flux estimator (virtual stator flux) in order to improve the quality of energy and to attenuate the harmonic of the current.
&lt;/p&gt;
</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Deboucha, Abdelhakim</style></author><author><style face="normal" font="default" size="100%">Bentouhami, Larafi</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Super twisting sliding mode approach applied to voltage orientated control of a stand-alone induction generator</style></title><secondary-title><style face="normal" font="default" size="100%">Protection and Control of Modern Power SystemsProtection and Control of Modern Power Systems</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2021</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12 2021</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">6</style></volume><pages><style face="normal" font="default" size="100%">18</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">To enhance the robustness and dynamic performance of a self-excited induction generator (SEIG) used in a stand-alone wind energy system (WES), a virtual flux oriented control (VFOC) based on nonlinear super-twisting sliding mode control (STSMC) is adopted. STSMC is used to replace the conventional proportional-integral-Fuzzy Logic Controller (PI-FLC) of the inner current control loops. The combination of the proposed control strategy with space vector modulation (SVM) applied to a PWM rectifier brings many advantages such as reduction in harmonics, and precise and rapid tracking of the references. The performance of the proposed control technique (STSMC-VFOC-SVM) is verified through simulations and compared with the traditional technique (PI-FLC-VFOC-SVM). It shows that the proposed method improves the dynamics of the system with reduced current harmonics. In addition, the use of a virtual flux estimator instead of a phase-locked loop (PLL) eliminates the line voltage sensors and thus increases the reliability of the system.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">COMMANDE A FLUX VIRTUEL ORIENTE DE LA GENERATRICE ASYNCHRONE A CAGE DOUBLE ÉTOILE</style></title><secondary-title><style face="normal" font="default" size="100%">Rev. Roum. Sci. Techn.– Électrotechn. et Énerg</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2021</style></year></dates><urls><web-urls><url><style face="normal" font="default" size="100%">https://www.researchgate.net/profile/Yacine-Bendjeddou-2/publication/353889771_Electrotechnique_et_electroenergetique_COMMANDE_A_FLUX_VIRTUEL_ORIENTE_DE_LA_GENERATRICE_ASYNCHRONE_A_CAGE_DOUBLE_ETOILE/links/6116c0a01ca20f6f861e5319/Electrotechnique-et-elec</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">66</style></volume><pages><style face="normal" font="default" size="100%">71–76</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Cet article est consacré à l’étude des performances de la génératrice asynchrone à cage double étoile (GASDE) en site isolé. Le système de commande est composé d’une GASDE raccordé à un bus continu et une charge en sortie de deux redresseurs à commande MLI. Une étude comparative entre la technique de commande conventionnelle et la commande adaptée basée sur l’introduction de la SVM-PI-flou et un nouvel estimateur de flux (flux virtuel statorique) afin d’améliorer la qualité d’énergie et d’atténuer les harmoniques du courant</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Improved field oriented control for stand alone dual star induction generator used in wind energy conversion</style></title><secondary-title><style face="normal" font="default" size="100%">Engineering Review</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2020</style></year><pub-dates><date><style  face="normal" font="default" size="100%">04</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">https://hrcak.srce.hr/236550</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">40</style></volume><pages><style face="normal" font="default" size="100%">34</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">This paper presents a novel direct rotor flux oriented control with online estimation of magnetizing current and magnetizing inductance applied to self-excited dual star induction generator equipping a wind turbine in remote sites. The induction generator is connected to nonlinear load through two PWM rectifiers. The fuzzy logic controller is used to ensure the DC bus voltage a constant value when changes in speed and load conditions. In this study, a performance comparison between the conventional approach and the novel approach is made. The proposed control strategy is validated by simulation in Matlab/Simulink.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">BENDJEDDOU, YACINE</style></author><author><style face="normal" font="default" size="100%">Abdessemed, Rachid</style></author><author><style face="normal" font="default" size="100%">MERABET, ELKHEIR</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Improved field oriented control for stand alone dual star induction generator used in wind energy conversion</style></title><secondary-title><style face="normal" font="default" size="100%">Engineering ReviewEngineering Review</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2020</style></year><pub-dates><date><style  face="normal" font="default" size="100%">04 2020</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">40</style></volume><pages><style face="normal" font="default" size="100%">34</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">This paper presents a novel direct rotor flux oriented control with online estimation of magnetizing current and magnetizing inductance applied to self-excited dual star induction generator equipping a wind turbine in remote sites. The induction generator is connected to nonlinear load through two PWM rectifiers. The fuzzy logic controller is used to ensure the DC bus voltage a constant value when changes in speed and load conditions. In this study, a performance comparison between the conventional approach and the novel approach is made. The proposed control strategy is validated by simulation in Matlab/Simulink.</style></abstract></record></records></xml>